• 中国核心期刊(遴选)数据库收录期刊
  • 中文科技期刊数据库收录期刊
  • 中国期刊全文数据库收录期刊
  • 中国学术期刊综合评价数据库统计源期刊等

中国药物评价 ›› 2026, Vol. 43 ›› Issue (3): 184-184-188.doi: 10.2095-3593.2026.060001

• 评价技术与方法 • 上一篇    下一篇

辛芳鼻炎胶囊中马兜铃酸Ⅰ测定方法研究及风险评估

茹庆国, 李海燕, 刘亚楠, 蒋芦荻, 黄霞, 王海波*   

  1. [河南省药品医疗器械检验院(河南省疫苗批签中心), 河南省中药质量控制工程研究中心, 河南 郑州 450018
  • 收稿日期:2026-01-12 修回日期:2026-04-22 接受日期:2026-08-05 出版日期:2026-06-28 发布日期:2026-08-12
  • 基金资助:
     2023年国家药品抽检(中央补助地方经费项目);河南省市场监督管理局科技计划项目(HNSCJ GK202425)

Research on the Determination Method and Risk Assessment of Aristolochic Acid Ⅰin Xinfang Biyan Capsules

RU Qingguo, LI Haiyan, LIU Yanan, JIANG Ludi, HUANG Xia, WANG Haibo*   

  1. Henan Institute for Drug and Medical Device Control (Henan Vaccine Issuance Center),Henan Province Engineering Research Center of Quality Control of Traditional Chinese Medicine, Henan Zhengzhou 450018, China
  • Received:2026-01-12 Revised:2026-04-22 Accepted:2026-08-05 Online:2026-06-28 Published:2026-08-12

摘要: 目的:建立辛芳鼻炎胶囊中马兜铃酸Ⅰ的高效液相色谱-质谱测定法,为该品种安全性控制提供理论依据。方法:采用Waters ACQUITY UPLC HSS T3(2.1 mm×100 mm,1.8 μm)色谱柱,以甲醇-0.1%甲酸(含1 mmol·L-1乙酸铵)溶液为流动相,梯度洗脱,流速为0.3 mL·min-1,电喷雾离子源正离子模式,采用多反应监测,以外标法定量。结果:马兜铃酸Ⅰ在0.320 9~32.092 5 μg·mL-1范围内线性关系良好(r2=0.999 5),平均回收率为95.04%,104批样品均检出马兜铃酸Ⅰ,含量为7.91~90.75 ng·g-1。结论:该方法灵敏、准确、可靠,专属性强,可用于辛芳鼻炎胶囊中马兜铃酸Ⅰ的限量检查。

关键词: font-size:medium, ">辛芳鼻炎胶囊;马兜铃酸Ⅰ;安全性;高效液相色谱-质谱法;限量检查

Abstract: Objective: To establish an high performance liquid chromatography-mass spectrometry method for the determination of aristolochic acid Ⅰ in xinfang biyan capsules, and provide theoretical basis for its safety control. Methods:Waters ACQUITY UPLC HSS T3 (2.1 mm×100 mm, 1.8 μm) column was used. Methanol-0.1% formic acid (containing 1 mmol·L-1 ammonium acetate) solution was used as mobile phase, gradient elution, flow rate of 0.3 mL·min-1, positive ion mode of electric spray ion source, multi reaction monitoring, external standard determination. Results: The linear relationship of aristolochic acid I was good within the range of 0.320 9-32.092 5 μg·mL-1 (r2=0.999 5), with an average recovery rate of 95.04%. Aristolochic acid I was detected in all 104 batches of samples, with a content of 7.91-90.75 ng·g-1. Conclusion: This method is sensitive, accurate, reliable, and highly specific, and can be used for the limited detection of aristolochic acid I in xinfang biyan capsules.

Key words: font-size:medium, "> , Xinfang biyan capsules; Aristolochic acid Ⅰ; Safety; High performance liquid chromatography-mass spectrometry; Limit test