Quantitative Determination of Bacterial Endotoxin in Posaconazole Active Pharmaceutical Ingredients by Kinetic Chromogenic Assay

  1. 1.Jiangxi Institute for Drug Control, NMPA Key Laboratory of Quality Evaluation of Traditional Chinese Patent Medicine, Jiangxi Province Engineering Research Center of Drug and Medical Device Quality, Jiangxi Nanchang 330029, China; 2.Jiangxi Qingfeng Pharmaceutical Co.Ltd, Jiangxi Ganzhou 330029, China
  • Received:2023-12-18 Revised:2024-01-24 Online:2024-04-28 Published:2024-04-28

摘要: 目的:以动态显色法定量检测不溶于水的泊沙康唑原料药中细菌内毒素的含量。方法:根据注射液临床用量从严拟订沙康唑原料药限值为0.25 EU·mg-1,以稀释液(二甲基亚砜∶RIPA强裂解液=1∶1)为溶剂处理泊沙康唑原料,采用两个不同厂家的动态显色法鲎试剂,依据《中国药典》2020年版四部通则1143(方法2光度测定法之动态显色法)要求,确定样品不干扰的浓度,最后对3批样品的细菌内毒素进行定量检测。结果:两个厂家的鲎试剂标准曲线|r|均大于0.980;样品质量浓度≤0.02 mg·mL-1时,细菌内毒素回收率在范围内;3批样品的细菌内毒素定量检测结果均符合要求。结论:以0.25 EU·mg-1为限值,动态显色法用于不溶于水的泊沙康唑原料药细菌内毒素定量检测,方法可行,过程可控。

关键词: font-size:medium, ">泊沙康唑;细菌内毒素;动态显色法;不溶于水;原料药;鲎试剂

Abstract: Objective: To establish a kinetic chromogenic method for the quantification of bacterial endotoxin in water-insoluble active pharmaceutical ingredients(API) of posaconazole. Methods:Based on the clinical dosage of posaconazole injection, a strict limit of 0.25 EU·mg-1 for the posaconazole API was formulated. The posaconazole API was dissolved with a diluent (dimethyl sulfoxide: RIPA strong lysis solution=1∶1) as a solvent, and kinetic chromogenic limulus amebocyte lysate reagents from two manufacturers were used. According to method 2(photometry) in the general rule 1143 in the Chinese Pharmacopoeia(2020 Edition,Volume Ⅳ), the mass concentration range of the sample was determined using the kinetic chromogenic assay . Finally, the bacterial endotoxin of three batches of samples was quantitatively detected. Results:The absolute correlation coefficients of the standard curves of limulus amebocyte lysate from two manufacturers were greater than 0.980. When the sample mass concentration was ≤0.02 mg·mL-1, the recoveries of bacterial endotoxin were in the range ; The quantitative detection results of bacterial endotoxin in three batches of samples all met the requirements. Conclusion:With a limit of 0.25 EU·mg-1, the kinetic chromogenic assay is feasible and controllable for the quantitative determination of bacterial endotoxin in water insoluble posaconazole API.

Key words: font-size:medium, ">Posaconazole; Bacterial Endotoxin; Kinetic Chromogenic Assay; Insoluble; Active Pharmaceutical Ingredients; Limulus Amebocyte Lysate