GC法测定复方水杨酸樟碘溶液中樟脑、薄荷脑、苯酚的含量

王鹏1, 钟振华1, 刘彭浩邦3, 陈雨萍1,2, 程奇珍1*   

  1. 1. 江西省药品检验检测研究院,国家药品监督管理局中成药质量评价重点实验室,
         江西省药品与医疗器械质量工程技术研究中心, 江西 南昌 330029;
    2. 江西中医药大学药学院, 江西 南昌 330004;
    3. 广东药科大学, 广东 广州 510006
  • 收稿日期:2020-03-04 修回日期:2020-06-13 出版日期:2020-08-28 发布日期:2020-09-21
  • 基金资助:
    国家药品标准提高研究项目(食药监办药化管[2017]139号)

Determination of Camphor Menthol and Phenol in Compound Salicylic Acid Iodine Solution by GC

  1. 1. Jiangxi Institute for Drug Control, NMPA Key Laboratory of Quality Evaluation of Traditional Chinese Patent Medicine,
         Jiangxi Province Engineering Research Center of Drug and Medical Device Quality, Jiangxi Nanchang 330029, China;
    2. School of Pharmacy of Jiangxi University of Traditional Chinese Medicine, Jiangxi Nanchang 330004, China;
    3. Guangdong Pharmaceutical University, Guangdong Guangzhou 510006, China
  • Received:2020-03-04 Revised:2020-06-13 Online:2020-08-28 Published:2020-09-21

摘要: 目的:建立气相色谱(GC)法测定复方水杨酸樟碘溶液中樟脑、薄荷油和苯酚的含量,为修订现行国家药品标准中的含量测定方法提供参考和依据。方法:采用色谱柱为KB-WAX 30 m×0.530 mm×3.00 μm毛细管色谱柱;检测器:FID检测器;进样口温度:220 ℃;升温程序:初始温度为120 ℃,维持15 min,以50 ℃·min-1的速率升温至220 ℃,维持15 min;检测器温度:300 ℃;载气流速:3.0 mL·min-1;进样体积:1 μL。结果:樟脑在0.075 17~4.510 mg·mL-1 、薄荷脑在0.006 13~0.245 3 mg·mL-1、苯酚在0.075 17~4.510 mg·mL-1范围内,线性关系良好(r>0.999)平均回收率分别为99.1%(RSD=0.8%)、99.4%(RSD=1.0%)和99.6%(RSD=0.9%)。结论:本方法灵敏、准确、重现性好,可用于复方水杨酸樟碘溶中樟脑、薄荷油和苯酚的测定。
 

关键词: font-size:medium, ">复方水杨酸樟碘溶液;樟脑;薄荷脑;苯酚;气相色谱;含量测定

Abstract: Objective: To establish GC method for determination of Camphor Menthol and Phenol in Compound salicylic acid iodine solution. Methods:GC was used by KB-WAX 30 m×0.530 mm×3.00 μm Capillary column.The detector was FID Inlet temperature was 220 ℃. The temperature program was as follows: the initial column temperature was 120 ℃, kept for 5min,and then risen to 220 ℃ with a rate of 50 ℃·min-1and kept for 15 min. The detector temperature was 300 ℃. The follow rate was 3.0 mL·min-1 and the injection volume was 1 μL. Results:The linear equations of Camphor Menthol and Phenol were in good linear range (r>0.999). The average recovery of Camphor Menthol and Phenol was 99.1%(RSD=0.8%)、 99.4%(RSD=1.0%)and 99.6%(RSD=0.9%). Conclusion: The method is sensitive and accurate with good stability,which can be used to determine the contents of Camphor 、Menthol and Phenol in compound salicylic acid iodine solution.

Key words: font-size:medium, ">Compound salicylic acid iodine solution; Camphor; Menthol; Phenol; GC; Content determination